A Study on the Effect of Environmetal Conditions on the Data Quality of Scanned Images Collected from the 3D Human Body Light Scanners

Thi Nhung Nguyen1,2, Thanh Thao Phan1,
1 Hanoi University of Science and Technology - No. 1, Dai Co Viet Str., Hai Ba Trung, Ha Noi, Viet Nam
2 Hung Yen University of Technical Education – Dan Tien, Khoai Chau, Hung Yen, Viet Nam

Main Article Content

Abstract

This article presents the results of the study on the influence of environmental conditions on the quality of human body scan images collected from 3D scanners using structured light with impact factors including: the scanning distance, backdrop color and environmental light intensity. In this paper, we used Meshlab software for image grading. We also used grayscale valueof Histogram diagram and thenumber of 3D scanned pixels which are determined to evaluate the data quality collected from the 3D human body light scanners. In addition, the study used Design Expert 6.0 software for analyzing collected data and checked the effect of those factors. The experimental results are given to clarify the effect of considered factors.

Article Details

References

[1] Nguyen Thi Nhung, Nguyen Thi Kim Cuc, Nguyen Van Vinh, Phan Thanh Thao, Nguyen Thanh Hung, Pham Xuan Khai; Design and manufacturing of a structural light 3D scanner for human body size measurement; Proceedings of the national science and technology conference on mechanical – Transportation engineering (NSCMET 2016), 33-37 (10/2016).
[2] Tong, J., Zhou, J., Liu, L., Pan, Z., & Yan, H. (n.d.). Scanning 3D Full Human Bodies using Kinects, 4-18 (2012).
[3] Voisin, S., Foufou, S., Truchetet, F., Page, D., & Abidi, M. (2017). Study of ambient light influence for three-dimensional scanners based on structured light, 1-3, 46 (March 2007).
[4] Koepke, J., Hu, X., Muenke, C., Schulten, K., & Michel, H. (n.d.). The crystal structure of the lightharvesting complex II (B800–850) from Rhodospirillummolischianum, 3, 581–597 (27 Mar 1996).
[5] Nguyen Thi Ngoc Quyen; Research and application of indirect measurement method and system construction 2D body size male students serving the garment industry; Journal of Science and Technology, No. 108 (2015).
[6] Hilton, A., Beresford, D., Gentils, T., Smith, R.J., Sun W. and Illingworth J.; Whole-body modelling of people from multiview images to populate virtual worlds. The Visual Computer (2000) 16:411 – 436, Springer-Verlag (2000).
[7] Repository, I.; Collection of anthropometry from older and physically impaired persons: traditional methods versus TC2 3-D body scanner (2012).
[8] Impact of Scanning Surfaces on Underwater Laser Scanners. 2G Robotics (2013).
[9] Dragan, D., Mihic, S., Anisic, Z., & Lukovic, I.; Role of Background Subtraction in Creating Human Body Point Clouds from Photographs, (October), 27–28 (2015).
[10] Nguyen Thanh Hai; Image processing; National University Publishing House. Ho Chi Minh City (2016).
[11] Zaimovic-uzunovic, N., & Lemes, S.; Influences of surface parameters on laser 3D scanning, 9-12 (2010).
[12] Bui Minh Tri; Mathematical planning; Science and Technics Publishing House; Hanoi (2001).